Short answer. A company network installation in Algeria in 2027 holds five things. Cabling: outlets numbered at both ends, in Category 6 or 6A, brought back to a patch cabinet, each one tested, with fibre as soon as a run exceeds 90 metres. Managed switches in the cabinet, powering the Wi-Fi access points, phones and cameras through the cable. Separated networks: workstations, telephony, servers, cameras, guests, administration, with written rules between them. Wi-Fi made of wired access points, placed from measurements, room by room. An edge: a firewall, two internet links from two operators with automatic failover, a UPS, monitoring. And at the end an acceptance: six checks and a file that stays with the company. This guide gives the plan, the figures needed to read a quote, and what to demand before signing.
It is for the manager of a company with ten to two hundred workstations, the business moving in or opening a warehouse, a branch or a clinic, the one whose network has “more or less worked” for years, and the founder living in France who is equipping offices in Algeria from a distance. The technical limits quoted are those of the standards as public references describe them: a copper permanent link of 90 metres plus 10 metres of patch cords, 10 gigabits up to 55 metres on Category 6 and up to 100 metres on Category 6A, 15.4 watts per port for PoE and 30 for PoE+. The equipment, powers, durations and measurements in the example are constructed to show the reasoning, not surveyed at a client's. Prices of imported hardware move too fast to print: a half-day survey gives a firm quote. Regulation, authorisations and operator contracts are outside the scope of this guide.
The network, drawn: two internet links, one firewall, three switches, six separated networks
The figure draws the network of a head office and its warehouse: thirty workstations, ninety-six outlets, fifty-eight devices connected.
Outlets and cabinet: each workstation has two outlets, each printer, access point, camera and time clock has its own, and a reserve is added: seventy-two outlets in the offices on three panels of twenty-four, twenty-four in the warehouse on one panel, ninety-six in all including eight spare. Each outlet carries the same number on the wall and on the panel. The warehouse is one hundred and forty metres away: beyond ninety metres of permanent link, copper no longer keeps its promise, so the run is optical fibre, with a small cabinet and its switch on site. The switches: one forty-eight-port PoE+ switch and one twenty-four-port switch in the offices, one twenty-four-port PoE+ switch in the warehouse; through the cable they power thirty phones, six access points and ten cameras.
The power budget is counted: in the offices, twenty-six phones at six watts, four access points at sixteen and four cameras at eight make two hundred and fifty-two watts out of the three hundred and seventy the example switch can supply; in the warehouse, one hundred and four out of one hundred and ninety-five. A switch whose budget is exceeded shuts ports down, and it is a camera or an access point that goes dark without warning. Separated networks: six logical networks (VLANs) on the same cables; telephony goes first, cameras and time clocks have no internet access, guest Wi-Fi sees only the internet. The two links: fibre from one operator and a 4G backup from another; the firewall probes each link every five seconds and fails over in twenty seconds, till and telephony first, guests cut off during backup. A till that carries on offline and an application designed for weak networks make this failover almost invisible.
«A company network is not a more powerful box: it is numbered outlets, separated networks, two links, and a failover provoked before signing.»
Six real situations, and what the network must do
Each row is a sentence heard in a company, and the answer is a network decision, not one more device.
Everything crawls on Sunday at 9: three small unmanaged switches in a chain share a single cable to the box; when everyone logs in, that cable saturates, and nobody can see it. Managed switches in the cabinet give one uplink per floor, and throughput and errors are read port by port; a damaged cable is found in ten minutes instead of a week. Wi-Fi drops in the meeting room: the box is at the end of the corridor and the repeater repeats a signal that is already weak, often halving the throughput; the answer is a wired access point on the ceiling, placed from a measurement. Internet goes down, everything stops: a second link from another operator, on another medium, and a firewall that fails over by itself; the backup does not need the main link's speed, it needs the till, the phones and email to get through.
A visitor can see the cameras: on a flat network, a visitor's phone, a camera still on its factory password and the accounting server are neighbours; with separated networks, what does not need to talk to each other does not, and an infected workstation does not spread everywhere, which also limits the damage of ransomware, alongside tested backups. Nobody knows which cable goes where: each outlet is numbered at both ends, the patching plan says which switch port serves which outlet, and the file belongs to the company, not to the installer. A power cut switches everything off: the UPS is sized on the cabinet's real load and its runtime is measured, fourteen minutes in the example; the server shuts down cleanly before the battery runs out, and when power returns the equipment restarts in order, network first.
Wi-Fi, measured: one box at the end of the corridor against two wired access points per floor
The figure shows the same floor, measured before and after, room by room.
The measurement: Wi-Fi signal is read in dBm, a negative figure; the closer to zero, the stronger the signal. A mark commonly used by manufacturers for voice and video is −67 dBm: above it, a call holds; below it, it breaks up. With the box at the end of the corridor, reception is at −48 and the meeting room at −84: four rooms out of eight are below the mark, and they are precisely the ones where clients are received. Why the repeater fixes nothing: it picks up an already weak signal and re-emits it; the room shows more bars, but the useful throughput remains that of the weakest hop.
Wired access points: two per floor, on the corridor ceiling, each on its own outlet and powered by the switch; the eight rooms move to between −49 and −56. The access points are set on channels that do not overlap: on 2.4 GHz only three are in common use, 1, 6 and 11; most traffic therefore goes over 5 GHz, where there is more room, and Wi-Fi 6 works on both bands. The same network name is broadcast everywhere: a phone moves from one access point to the next without the call dropping. Two names, not ten: one network for the company, tied to employee accounts, one for guests, which sees only the internet. In the warehouse: metal racking and height change everything; the two access points are placed after a measurement with the racks full, where the terminals of the field application work.
A company network, in five layers
Separated networks are the accented layer: cabling and switches make it possible, Wi-Fi and the firewall apply it.
Cabling, cabinet, power. A Category 6 cable carries one gigabit up to 100 metres of channel, that is 90 metres of permanent link and 10 of patch cords, and 10 gigabits up to 55 metres; Category 6A carries 10 gigabits over the full 100 metres. For workstations, Category 6 is ample; for runs to Wi-Fi access points and between cabinets, 6A or fibre leave headroom. The cable is solid copper, laid in cable trays, away from power cables; the cabinet locks, it is ventilated, and the UPS is chosen from the measured load. Switches and PoE. The standards give 15.4 watts per port for PoE and 30 for PoE+, slightly less at the device; you add up the equipment, compare with the switch budget, and keep a margin.
Separated networks. VLANs are logical networks on the same cables; the standard allows up to 4,094 of them, a mid-sized company uses six to ten. Separation is only worth the firewall rules between them: workstations reach the server and the printers, cameras reach only the recorder, guests reach only the internet. Wi-Fi. Wired access points, placed from measurements, managed together. Edge and operation. The firewall carries the two links, the failover, the rules and encrypted remote access for the director or a branch; monitoring warns when a link drops, when a port throws errors, when the UPS goes on battery, on the same logic as monitoring an application; configurations are backed up, and administration passwords sit in a vault the company holds, with two named accounts as in the guide on roles.
«What does not need to talk to each other does not: the visitor sees only the internet, the camera sees only the recorder, and the infected workstation does not wander.»
A network installation in 2027, in weeks
Five weeks in the example, the first with nothing installed, and two for the cabling, because it is what stays.
Week 1, survey and plan: site visit, count of workstations and devices, outlet plan room by room, Wi-Fi measurements, cable routes and cabinet location, addressing and separated-network plan, equipment list; the quote that comes out is read line by line: price per outlet installed and tested, active equipment with its reference, configuration days, acceptance. Weeks 2 and 3, cabling and cabinet: pulling, fitting outlets, terminating panels, fibre to the warehouse; each outlet is tested and its result recorded. The company keeps working meanwhile: the old network stays in service.
Week 4, active equipment: switches, separated networks, firewall, access points, second link; everything is configured and tried beside the old network, with two or three pilot workstations. Week 5, cutover and acceptance: the migration happens one evening or weekend, department by department; the next morning someone is on site; then come the six checks and the handover of the file. A ten-workstation floor takes less than five weeks; a multi-storey building in use, a clinic or a factory takes more, mostly for the cabling. Lead times for imported hardware are checked before the cutover date is fixed.
Acceptance: six checks before signing
The accented check is the provoked outage: a backup that has never been triggered is not a backup.
- What the manager sees: a one-page diagram, the list of outlets, the state of both links, and an alert on their phone when a link drops or the UPS goes on battery.
- What the company no longer does: restart the box, hunt for which cable goes where, buy a repeater, wait for the internet to come back before taking payment, depend on one person who keeps it all in their head.
- What is measured: outlets tested out of outlets installed, signal per room, failover time, UPS runtime, PoE watts used out of watts available, free ports, incidents per month.
Every outlet tested: one report per outlet, with its length and result; an outlet that fails is redone, not “to be watched”. Wi-Fi measured: one value per room, door closed, marked on the plan; a room below the mark means an access point moved or added before signing. Internet cut on purpose: the fibre is unplugged one morning; the till carries on, the phones hold, the manager receives the alert, and the failover time is noted; then it is plugged back, and the return to the main link happens by itself.
Separation checked: from the guest Wi-Fi, someone tries to reach a camera, a printer, the server; nothing must answer. Power cut on purpose: the cabinet's supply is cut, the runtime is measured, and the server is seen to shut down cleanly and everything restart in order. File handed over: outlet plan, patching plan, addressing plan, network diagram, saved configurations, warranties and equipment references, and the administration passwords, handed to the company. This file is what makes it possible, three years on, to add ten workstations or change provider without rediscovering everything.
- How much does a company network installation cost in Algeria?
- The price depends on four things: the number of outlets and how hard the pulling is (false ceiling, trunking, distances), the active equipment (PoE switches, firewall, access points), special runs (fibre to another building) and the configuration with acceptance. Hardware is imported and its price moves; that is why this guide gives no rate. A serious quote is read line by line: price per outlet installed, numbered and tested, reference of each device, configuration days, acceptance and file. A one-line quote for a “complete network” lets you compare nothing.
- Category 6 or Category 6A?
- In the usual description of the standards, Category 6 carries one gigabit up to 100 metres and 10 gigabits up to 55 metres; Category 6A carries 10 gigabits up to 100 metres. For office workstations, Category 6 is enough. For runs to Wi-Fi access points, between cabinets and to servers, 6A or fibre give headroom for the years the cable will spend in the wall. Beyond 90 metres of permanent link, it is fibre.
- Can we keep the operator's box?
- Yes, as the arrival point of the link, in front of the firewall. It must no longer be the heart of the network: no company Wi-Fi on it, no workstations plugged into it. Depending on the model and the plan, it can be set as a simple gateway; that is to be checked with the operator.
- Can Wi-Fi replace cabling?
- For what moves, yes: phones, laptops, warehouse terminals. For what stays in place, no: fixed workstations, IP phones, printers, cameras and tills are cabled. Each Wi-Fi access point itself needs its cable; Wi-Fi without cabling is a network of repeaters.
- What happens when the internet goes down?
- The firewall notices within seconds that the main link no longer answers and moves traffic to the backup link; twenty seconds in the example. The till, the phones and email go first; guests and updates wait. What is on site, file server, printers, software installed in the office, never depended on the internet and carries on. The backup has a limited data volume: it is there to hold, not to work as usual for a week.
- Should we have a server on site or put everything in the cloud?
- The network does not settle that question, it makes both directions possible: with two links, a hosted application stays reachable; with a server or NAS on site, files stay fast even when the internet is slow. The choice is made application by application, as the guide on hosting in Algeria or Europe explains; in both cases, backups are tested.
- What if the company has several sites?
- Each site has its network drawn the same way, and the sites are linked by an encrypted tunnel between their firewalls, across the internet. Addresses are planned from the start so they do not overlap from one site to another. A branch then sees the head-office server as if it were in the building, within the limit of its own link's speed, which also has its backup.
- Who keeps the passwords and the documentation?
- The company. The file handed over at acceptance contains the plans, the addressing, the saved configurations and the administration access, in a password vault whose key the manager holds. The provider has a named account, which can be closed. A network whose passwords are known only to one outside person does not belong to the company.